Performance Characterization of an Actively Cooled Repetitive Transcranial Magnetic Stimulation Coil for the Rat

J, Parthoens; J, Verhaeghe; S, Servaes; A, Miranda; S, Stroobants; S, Staelens
Abstract:
OBJECTIVES: This study characterizes and validates a recently developed dedicated circular rat coil for small animal repetitive Transcranial Magnetic Stimulation (rTMS). MATERIALS AND METHODS: The electric (E) field distribution was calculated in a three-dimensional (3D) spherical rat head model and coil cooling performance was characterized. Motor threshold (MT) in rats (n = 12) was determined using two current directions, MT variability (n = 16) and laterality (n = 11) of the stimulation was assessed. Finally, 2-deoxy-2-((18) F)fluoro-D-glucose ([(18) F]-FDG) small animal Positron Emission Tomography (µPET) after sham and 1, 10, and 50 Hz rTMS stimulation (n = 9) with the new Cool-40 Rat Coil (MagVenture, Denmark) was performed. RESULTS: The coil could produce high E-fields of maximum 220 V/m and more than 100 V/m at depths up to 5.3 mm in a ring-shaped distribution. No lateralization of stimulation was observed. Independent of the current direction, reproducible MT measurements were obtained at low percentages (27 ± 6%) of the maximum machine output (MO, MagPro X100 [MagVenture, Denmark]). At this intensity, rTMS with long pulse trains is feasible (1 Hz: continuous stimulation; 5 Hz: 1000 pulses; 10 Hz and 50 Hz: 272 pulses). When compared to sham, rTMS at different frequencies induced decreases in [(18) F]-FDG-uptake bilaterally mainly in dorsal cortical regions (visual, retrosplenial, and somatosensory cortices) and increases mainly in ventral regions (entorhinal cortex and amygdala). CONCLUSION: The coil is suitable for rTMS in rats and achieves unprecedented high E-fields at high stimulation frequencies and long durations with however a rather unfocal rat brain stimulation. Reproducible MEPs as well as alterations in cerebral glucose metabolism following rTMS were demonstrated.
Patologie/Applicazioni:
Anno:
2016
Tipo di pubblicazione:
Articolo
Parola chiave:
neuromodulazione
Testata scientifica:
Neuromodulation
DOI:
10.1111/ner.12387

La nostra storia

GEA soluzioni si affaccia nel 2013 al mercato della strumentazione medicale di alto livello tecnologico ma la sua storia parte da più lontano, clicca qui per approfondire.  

GEA SOLUZIONI SRL
via Issiglio 95/10, Torino
Tel.: 011 5821948
Fax: 011 0433281
Email: info @ geasoluzioni.it

P. IVA IT11696920013
REA TO1233648

Tutti i prodotti esposti sul sito geasoluzioni.it con relativi sottodomini ed aventi la natura di dispositivi medici, dispositivi medico diagnostici, presidi medico chirurgici, medicazioni per uso esterno, nonché tutti i contenuti del sito www.geasoluzioni.it (testi, immagini, foto, disegni, allegati, descrizioni e quant’altro) non hanno carattere né natura di pubblicità. Tutti i contenuti devono intendersi e sono di natura esclusivamente informativa e volti esclusivamente a portare a conoscenza dei clienti o dei potenziali clienti in fase di pre-acquisto i prodotti venduti da GEA soluzioni s.r.l. attraverso la rete. Nessun contenuto delle pagine del sito deve essere inteso come materiale pubblicitario, teso ad influenzare in qualsivoglia maniera una decisione di acquisto.

EU-Cookies

Copyright © 2024 GEA SOLUZIONI SRL. Tutti i diritti riservati.

Search