Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)

JP, Lefaucheur; A, Antal; SS, Ayache; DH, Benninger; J, Brunelin; F, Cogiamanian; M, Cotelli; D, De Ridderij; R, Ferrucci; B, Langguth; P, Marangolo; V, Mylius; MA, Nitsche; F, Padberg; U, Palm; E, Poulet; A, Priori; S, Rossi; M, Schecklmann; S, Vanneste; U, Ziemann; L, Garcia-Larrea; W, Paulus
Abstract:
A group of European experts was commissioned by the European Chapter of the International Federation of Clinical Neurophysiology to gather knowledge about the state of the art of the therapeutic use of transcranial direct current stimulation (tDCS) from studies published up until September 2016, regarding pain, Parkinson’s disease, other movement disorders, motor stroke, poststroke aphasia, multiple sclerosis, epilepsy, consciousness disorders, Alzheimer’s disease, tinnitus, depression, schizophrenia, and craving/addiction. The evidence-based analysis included only studies based on repeated tDCS sessions with sham tDCS control procedure; 25 patients or more having received active treatment was required for Class I, while a lower number of 10–24 patients was accepted for Class II studies. Current evidence does not allow making any recommendation of Level A (definite efficacy) for any indication. Level B recommendation (probable efficacy) is proposed for: (i) anodal tDCS of the left primary motor cortex (M1) (with right orbitofrontal cathode) in fibromyalgia; (ii) anodal tDCS of the left dorsolateral prefrontal cortex (DLPFC) (with right orbitofrontal cathode) in major depressive episode without drug resistance; (iii) anodal tDCS of the right DLPFC (with left DLPFC cathode) in addiction/craving. Level C recommendation (possible efficacy) is proposed for anodal tDCS of the left M1 (or contralateral to pain side, with right orbitofrontal cathode) in chronic lower limb neuropathic pain secondary to spinal cord lesion. Conversely, Level B recommendation (probable inefficacy) is conferred on the absence of clinical effects of: (i) anodal tDCS of the left temporal cortex (with right orbitofrontal cathode) in tinnitus; (ii) anodal tDCS of the left DLPFC (with right orbitofrontal cathode) in drug-resistant major depressive episode. It remains to be clarified whether the probable or possible therapeutic effects of tDCS are clinically meaningful and how to optimally perform tDCS in a therapeutic setting. In addition, the easy management and low cost of tDCS devices allow at home use by the patient, but this might raise ethical and legal concerns with regard to potential misuse or overuse. We must be careful to avoid inappropriate applications of this technique by ensuring rigorous training of the professionals and education of the patients.
Patologie/Applicazioni:
Anno:
2017
Tipo di pubblicazione:
Articolo
Parola chiave:
tDCS; NIBS; Neuromodulazione; livelli di raccomandazione A B C
Testata scientifica:
Clinical Neurophysiology
Nota:
Un gruppo di esperti europei ha esaminato le prove attuali sull'efficacia terapeutica della tDCS. Si suddividono le principali evidenze cliniche per malattie neurologiche in evidenze di tipo A (efficacia evidente), tipo B (probabile efficacia) e tipo C (possibile efficacia). In particolare, sono state trovate prove di livello B per fibromialgia, depressione e craving.
DOI:
doi.org/10.1016/j.clinph.2016.10.087

La nostra storia

GEA soluzioni si affaccia nel 2013 al mercato della strumentazione medicale di alto livello tecnologico ma la sua storia parte da più lontano, clicca qui per approfondire.  

GEA SOLUZIONI SRL
via Issiglio 95/10, Torino
Tel.: 011 5821948 / 011 4463853
Fax: 011 0433281
Email: info @ geasoluzioni.it

P. IVA IT11696920013
REA TO1233648

Tutti i prodotti esposti sul sito geasoluzioni.it con relativi sottodomini ed aventi la natura di dispositivi medici, dispositivi medico diagnostici, presidi medico chirurgici, medicazioni per uso esterno, nonché tutti i contenuti del sito www.geasoluzioni.it (testi, immagini, foto, disegni, allegati, descrizioni e quant’altro) non hanno carattere né natura di pubblicità. Tutti i contenuti devono intendersi e sono di natura esclusivamente informativa e volti esclusivamente a portare a conoscenza dei clienti o dei potenziali clienti in fase di pre-acquisto i prodotti venduti da GEA soluzioni s.r.l. attraverso la rete. Nessun contenuto delle pagine del sito deve essere inteso come materiale pubblicitario, teso ad influenzare in qualsivoglia maniera una decisione di acquisto.

EU-Cookies

Copyright © 2024 GEA SOLUZIONI SRL. Tutti i diritti riservati.

Search